Specifications

Every number a designer needs.

UTS, jacking force, duct and cone geometry, anchorage spacing and the anti-burst spiral for all five AT post-tensioning anchorage models — straight from the TYROS data sheet.

Data sheet

AT anchorage table

Letters reference the dimension diagram below. Scroll sideways on small screens.

TYROS AT anchorage technical specifications
SrAnchor TypeUTSton80% of UTStonDuct DiammAnchor Cone Size (A × A)AmmMin Edge DistanceBmmSpacing Between AnchoragesCmmPocket DepthDmmPCD of HolesEmmSpiral ReinforcementFmmLength of SpiralGmmSpiral BarHmmNo. of TurnsNPitch of SpiralJmm
112 AT 15400320902452003006220025054016960
219 AT 13400320902451983256220025054016960
312 AT 13320256752071482605217519048016860
44 AT 137560511451202204512515024016640
57 AT 13131105511451202204512515024016640
  • Letters A–J refer to the dimension diagram.
  • Dimensions in mm, forces in metric tons (units per industry convention; not stated on the source page).

Dimension diagram

Reading the letters

A
Anchor cone size (A × A)
B
Min edge distance
C
Spacing between anchorages
D
Pocket depth
E
PCD of holes
F
Spiral reinforcement Ø
G
Length of spiral
H
Spiral bar Ø
N
Number of turns
J
Pitch of spiral
A 245D 62SIDE SECTIONB 200C 300B 200C 300E 200ANCHORAGE LAYOUT · PLANF 250G 540J 60H 16N 9 turnsSPIRAL REINFORCEMENT

Values shown for 12 AT 15

Send us the tendon schedule. We'll send back the anchorage.

Anchorage specifications, anti-burst reinforcement details and the stressing methodology — for every contractor, on every job.

Need the tendons stressed too? See our post-tensioning stressing services.